| Additional Information |
: |
Piping: Max. Piping Length Feet (m): 245 ft (75 m)|Piping: Vapor Connection Size OD. Inch (mm): 5/8 (15.88)|Power Supply: 208/230 V/1 Phase/60 Hz|Refrigerant Data: Type: R-410A|Wire Gauge (AWG): 14 |
| Cooling at 95F: Maximum Capacity (BTUH) |
: |
42000 |
| Cooling at 95F: Maximum Power Input (W) |
: |
4270 |
| Cooling at 95F: Minimum Capacity (BTUH) |
: |
19000 |
| Cooling at 95F: Moisture Removal (Pints/h) |
: |
7.2 |
| Cooling at 95F: Power Factor (%) |
: |
88.4 |
| Cooling at 95F: Rated Power Input (W) |
: |
4270 |
| Cooling at 95F: Sensible Heat Factor (SHF) |
: |
0.76 |
| Efficiency: COP at 47F |
: |
3.5 |
| Efficiency: COP at 5F at Maximum Capacity |
: |
1.91 |
| Efficiency: EER |
: |
9.8 |
| Efficiency: HSPF |
: |
11 |
| Efficiency: SEER |
: |
15.3 |
| Electrical Communication Voltage S2-S3 (VDC) |
: |
12/24 V |
| Electrical Power Supply Voltage S1-S2 (VAC) |
: |
208/230 V |
| Guaranteed Operating Voltage Range (VAC) |
: |
198/253 V |
| Heating at 17F: Maximum Capacity (BTUH) |
: |
48000 |
| Heating at 17F: Maximum Power Input (W) |
: |
6700 |
| Heating at 17F: Rated Capacity (BTUH) |
: |
42400 |
| Heating at 17F: Rated Power Input (W) |
: |
4990 |
| Heating at 47F: Maximum Capacity (BTUH) |
: |
54000 |
| Heating at 47F: Maximum Power Input (W) |
: |
4870 |
| Heating at 47F: Minimum Capacity (BTUH) |
: |
18000 |
| Heating at 47F: Power Factor (%) |
: |
88.1 |
| Heating at 47F: Rated Capacity (BTUH) |
: |
48000 |
| Heating at 47F: Rated Power Input (W) |
: |
4010 |
| Heating at 5F: Maximum Capacity (BTUH) |
: |
48000 |
| Heating at 5F: Maximum Power Input (W) |
: |
7360 |
| Indoor Unit: Airflow Rate at Cooling (Dry) (CFM) |
: |
1040-1262-1485 |
| Indoor Unit: Airflow Rate at Cooling (Wet) (CFM) |
: |
Delete |
| Indoor Unit: Coating on Heat Exchanger |
: |
Delete |
| Indoor Unit: Condensate Lift Mechanism |
: |
Optional Accessory |
| Indoor Unit: Cooling Intake Air Temp Max/Min deg F |
: |
90 DB, 73 WB/66 DB, 59 WB |
| Indoor Unit: Drain Pipe Size Inch (mm) |
: |
3/4 FPT (19.05) |
| Indoor Unit: Drain Pump Max Lift Height Inch (mm) |
: |
Delete |
| Indoor Unit: External Finish Color |
: |
Galvanized Steel Cabinet-Powder Coated Slate Gray |
| Indoor Unit: External Static Pressure (in-WG) |
: |
0.3-0.5-0.8 |
| Indoor Unit: Fan Motor FLA |
: |
4.5 |
| Indoor Unit: Fan Motor Output (W) |
: |
430 |
| Indoor Unit: Heat Exchanger Type |
: |
Plate Fin Coil |
| Indoor Unit: Heating Intake Air Temp Max/Min deg F |
: |
82 DB/50 DB |
| Indoor Unit: MCA |
: |
5.63 |
| Indoor Unit: Remote Controller Included |
: |
No |
| Indoor Unit: Sound Pressure Level Cooling dB[A] |
: |
34 - 38 - 42 |
| Model |
: |
PVA-A |
| Piping: Liquid Connection Size OD. Inch (mm) |
: |
3/8 (9.52) |
| Piping: Max. Number of Bends |
: |
15 |
| Piping: Max. Piping Height Difference Feet (m) |
: |
100 (30) |